A blower-door fan is sealed into an exterior doorway, all the house vents are temporarily sealed, and the calibrated fan blows air out of the house creating a pressure difference between the inside and outside, which draws air into all of the inadequately sealed cracks, holes and penetrations. A pressure sensing device is used to measure the rate of pressure change/leakage. The data is entered into a standardized formula and the number of Natural Air Changes per Hour (NACH) is derived. Typical production-built homes built under current building codes will score at about 0.5NACH or higher (one complete air change every two hours). A well built, near zero energy home aims for a score of 0.1-0.2NACH. EarthCraft Virginia officials, including Chuk Bowles, Technical Director (tending to the pressure monitor above) and KC McGurren, Executive Director, supervised the testing of our home this week.